CONNECT-SET for emergency remote-maintenance FACTORY
Completely configured, everything for the FACTORY-side
OEM - Version (all accessories optional)
without PCMCIA-Slot for UMTS-/LAN-card
Remote-maintenance of systems/machines without the need for the IT-department
All equipment required for use on FACTORY-side are included in the package (including LAN-cable, plug-in power-supply, ...)
All devices preconfigured
Every SIM-card (also from the service technician's cell phone) can be used, no special requirement
Ideal package for every service technician who needs short-term on-site support on the system
Neutral shipping directly to your customer
No requirements for the user, work according to the motto:
"Unpack, switch on, work"
more...
ARTNR: 9372-OEM
TELE-PROFessional II worldwide use
EAN number: | 4260363240062 | |
HS-code: | 85389099 | |
Weight: | 2.05 kg |
Remote maintenance
TELE LINK NETWORK
|
||||||||
secured modem-protocol |
✓
|
✓
|
✓
|
|||||
additional software needed |
Siemens TS -Software
|
Siemens TS -Software
|
VPN-Client
|
VPN-Client
|
||||
Providing WinTELEPROF-software |
✓
|
✓
|
✓
|
|||||
modem |
analogue/ISDN
|
analogue
|
opt. via PCMCIA
|
analogue/GSM
|
analogue/ISDN/GSM
|
internet-connection
|
internet-connection
|
internet-connection
|
modem for world wide use |
✓
|
✓
|
✓
|
✓
|
✓
|
|||
interfaces | ||||||||
MPI/Profibus |
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
9600-12MBd
|
||||
RS232 |
2x
|
2x
|
2x
|
1x
|
1x
|
|||
TTY |
2x
|
2x
|
2x
|
1x
|
||||
PCMCIA |
2x (optionally)
|
1x
|
1x
|
|||||
Ethernet |
10/100BaseTx
|
1x
|
1x
|
5x
|
||||
USB |
2x
|
1x
|
||||||
LCD-display |
✓
|
✓
|
✓
|
✓
|
instead 10 LEDs
|
instead status-LED
|
instead webserver
|
instead webserver
|
supported PLC-protocols * | ||||||||
S7 |
✓
|
✓
|
✓
|
✓
|
✓
|
✓
|
||
S5 |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
||||
Pilz PSS |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
Allen-Bradley |
✓
|
✓ (optional)
|
✓ (optional)
|
|||||
AEG |
✓ (optional)
|
✓ (optional)
|
||||||
Bosch |
✓ (optional)
|
✓ (optional)
|
||||||
Telemecanique |
✓ (optional)
|
✓ (optional)
|
||||||
GE-Fanuc |
✓ (optional)
|
✓ (optional)
|
||||||
Klöckner-Moeller |
✓ (optional)
|
✓ (optional)
|
||||||
Mitsubishi |
✓ (optional)
|
✓ (optional)
|
||||||
SMS-sending/Pager(S5/S7) |
✓
|
✓
|
✓
|
✓ (no pager)
|
only for analogue / ISDN
|
|||
HMI-messaging module(S5/S7) |
✓
|
✓
|
||||||
SMS-receive with GSM |
✓
|
|||||||
DTMF with analogue |
✓
|
|||||||
e-mail-dispatch |
✓
|
✓
|
✓
|
|||||
FAX-dispatch(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
only for analogue / ISDN
|
||||
PLC-data coupling(S5/S7) |
✓
|
✓ (optional)
|
✓ (optional)
|
✓
|
✓
|
|||
ASCII-transfer from S5/S7 |
✓
|
✓ (optional)
|
✓ (optional)
|
only with ASCII-LAN
|
||||
internet-coupling |
✓
|
|||||||
Usage as dial-up-router |
✓
|
✓
|
||||||
power supply |
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
24V/DC
|
dimensions w x h x d (in mm) |
High: 67 x 280 x 170
FLAT: 300 x 175 x 70 |
300 x 175 x 66
|
235 x 162 x 37
|
90 x 162 x 54
|
40 x 125 x 115
|
42 x 15 x 65
|
65 x 43 x 17
|
154 x 92 x 28
|
* other PLC types on request |
Remote-maintenance of systems/machines without the need for the IT-department
All equipment required for use on FACTORY-side are included in the package (including LAN-cable, plug-in power-supply, ...)
All devices preconfigured
Every SIM-card (also from the service technician's cell phone) can be used, no special requirement
Ideal package for every service technician who needs short-term on-site support on the system
Neutral shipping directly to your customer
No requirements for the user, work according to the motto:
"Unpack, switch on, work"
Advantage:
• Monthly rent 10% of the list price
• No additional costs, SIM-card included with monthly rent
• No installation of additional software tools
• Avoidance of on-site maintenance-work through remote-access
• No PC required on site
• Switch on only, automatic connection establishment (no portal login)
• Access to every LAN participant, e.g. E.g. PLC (S5/S7/Bosch/Mitsubishi, ...), PC, ...
• Open WebInterface with keyword, no matter which subnet
• Workplaces at the same time in parallel on different participants on site
• Remote-access to customer systems without an intranet
• Connection without much effort
• Only your devices are visible in the cloud
• Encrypted transmission between the CONNECT-devices
• Quick and easy configuration with WebInterface, no unnecessary input masks
• Integrated firewall regulates access from the intranet to the machine network
• Remote access to all devices in the cloud
• Import / export configuration between devices in the cloud
• Integrated diagnostic tools on site for network-analysis
You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 15 watt |
Display: |
expressive LCD display 5 status LEDs |
Handling/Configuration: |
integrated keypad WEB-Browser |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBdTTY/20mA current loop (AG-TELE aktiv, PLC passiv) RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jackTTY/20mA current loop (100 % mechanically and electr. compatible) RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H) |
Integrated modem: |
33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem ISDN (Euro ISDN + 1TR6) |
Operating temperature: | 0 - 55°C |
Case: | powder coated metal case with mounting flange and DIN-rail mounting |
Dimensions: |
Flat 300 x 175 x 70 mm Hoch 67 x 280 x 170 mm |
Scope of delivery: |
Tele-Prof-II Power connector 3pins big |
accessories:
plus VAT. and shipping
S5-connecting cable 10m
for TELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 3m
forTELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 5m
for TELE-PROF, MINI-/PG-MUX-II
S5-connecting cable 6m
for TELE-PROF, MINI-/PG-MUX-II
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
plus VAT. and shipping
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
plus VAT. and shipping
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
plus VAT. and shipping
Analogue-telefone
Facilities management world wide – remote maintenance and diagnosis via telephone
PLC-remote maintenance also available from the car, with 12V power supply
The simple and quick router solution for automation
Analogue-telefone
Facilities management world wide – remote maintenance and diagnosis via telephone
PLC-remote maintenance also available from the car, with 12V power supply
Programming of S7-PLC’s via telephone from afar
The simple and quick router solution for automation
ISDN
The simple and quick router solution for automation
ISDN
The simple and quick router solution for automation
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
Remote maintenance of PPI, MPI and Profibus <=> analogue 56K-, ISDN-, GSM-Modem
plus VAT. and shipping
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
plus VAT. and shipping
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping
plus VAT. and shipping