EtherSens Energy-II for Rogowski-coils only with LAN
Capture and monitor energy-data
Energy-analysis (EN 50470-1 EN 50470-3)
2x L1, 2x L2, 2x L3, 2x N realtime analysis
Up to 8000 measurements / second
Hz / cos phi / power-factor
Energy consumption kWh
Only LAN-interface
For Rogwski-coils up to 0,5V
- Determining energy-efficiency
- Energy-analysis (EN 50470-1 EN 50470-3)
- 2x L1, L2, L3 and N realtime analysis
- up to 8000 measurements / second
- frequency Hz / cos phi / power-factor
more...
ARTNR: 9203-II-OW
EtherSens Energy-II for Rogowski-coils only with LAN
EAN number: | 4260363247252 | |
HS-code: | 85423190 | |
Weight: | 0.3 kg |
- Determining energy-efficiency
- Energy-analysis (EN 50470-1 EN 50470-3)
- 2x L1, L2, L3 and N realtime analysis
- up to 8000 measurements / second
- frequency Hz / cos phi / power-factor
- energy-measurement kW/h
- Data-transfer via TCP/IP in a DB in S7-PLC
- For Rogowski-spool
- For folding cores
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card
S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card
Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick
Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card
S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick
Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick
Detect the efficiency of your plant/machine by EtherSens-Energy-devices. Log the preset parameters and evaluate them then later. Find so unnecessary idle-times and increase so the efficiency.
Do you also need the energy-consumption of your plant or need to determine the cos phi? With the EtherSens Energy you can capture and record by using a Rogowski-coil or folding-core the required values.
Supply voltage: | 100 - 240V AC, 50 - 60 Hz |
Power consumption: | 5 watt |
Measurement: |
|
Display: |
WEB-Browser 1 status LED bicolor |
Handling/Configuration: | WEB-Browser |
Interfaces: |
8 x voltage-input (L1, L2, L3, N) 8 x distributor-terminal 8 x sensor-input (L+K- / B+W-terminal ever phase + N) Slot for microSD 10/100BaseTX RJ45-ethernet-plug Button for factory settings |
Overvoltage category: | CAT IV |
Insulation value network <=> mains voltage: |
1,5 KV |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case V0 |
Dimensions: | 100 x 112 x 90 mm |
Scope of delivery: |
EtherSens Energy-II |
sensors:
Rogowski-coil 5000A, 55mm
Cable hole: 55mm Cable length: 1,5m Shutter: click cap Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 35mm
Cable hole: 35mm Cable length: 1,5m Shutter: click cap Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 470mm, twist-lock Obsolete
Cable hole: 470mm Cable length: 2,5m Shutter: twist-lock Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 80mm
Cable hole: 80mm Cable length: 1,5m Shutter: click cap Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 35mm, twist-lock Obsolete
Cable hole: 35mm Cable length: 2,5m Shutter: twist-lock Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 80mm, twist-lock
Cable hole: 80mm Cable length: 2,5m Shutter: twist-lock Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
Rogowski-coil 5000A, 160mm, twist-lock Obsolete
Cable hole: 160mm Cable length: 2,5m Shutter: twist-lock Easy and fast installation with no interruptible power-lines
plus VAT. and shipping
extensions:
Extension Analog-IO V1.0
Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Segment-display for EtherSens
4 Digit 14 segment-display WHITE 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
plus VAT. and shipping
Gyro-Sensor 313 for EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Gyro-Sensor 312 for EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Temp./humidity/air-pressure for EtherSens
Measuring range: Temperature: -40 ...+85°C Humidity: 0...100% relative Feuchte Pressure: 300...1100 hPa 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
Sun-light-sensor for EtherSens
max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
plus VAT. and shipping
U-I-box for EtherSens
max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
plus VAT. and shipping
Extension LTE-modem
LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
plus VAT. and shipping
Extension with ext. galv. separated I2C 5V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
plus VAT. and shipping
Extension with ext. galv. separated I2C 3.3V
Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
plus VAT. and shipping
Extension RS485-IO
Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
plus VAT. and shipping
Extension TTY-IO
Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
plus VAT. and shipping
Extension RS232-IO
Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
plus VAT. and shipping
Extension RS422-IO
Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
plus VAT. and shipping
Extension Analog-IO V1.1
Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
plus VAT. and shipping
Extension 230V Relay-IO
Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
plus VAT. and shipping
Extension Digital-IO
Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
plus VAT. and shipping
Extension USB-port
USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
plus VAT. and shipping
accessories:
Patch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1
Cross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
Patch-cable 0.25m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
plus VAT. and shipping
Option Safe S7-PLC-data-transmission
Function extension for recognition of save data-transmission by toggle bit or counters in the S7-PLC. In case of a failure, a default configuration is mapped to the outputs.
plus VAT. and shipping
plus VAT. and shipping