PG-FOX
![](images/Homepage-Bilder/PG-FOX-232.png)
![](images/Homepage-Bilder/PG-FOX-232.png)
![](images/katalog/PGFOX-Kommunikation.png)
![](images/Homepage-Bilder/pgfox.png)
Recording of serial transmission lines for error analysis
active protocoll-recording for RS232-track to PC
with 2 COM-ports
- Listening in, logging and analysing of asynchronous communication protocols
- Versions for RS232, RS422/RS485 and TTY
- Maximum recording speed: 115200 baud for RS232 + RS422/RS485 + TTY
- Data output in HEX- or ASCII-format
- PC for operating software requires 2 serial COM ports
more...
variants:
ARTNR: 9362-1P
PG-FOX-PLUS RS-232
530,00 € plus VAT. and shipping
ARTNR: 9362-1P
PG-FOX-PLUS RS-232
EAN number: | 4260363242639 | |
HS-code: | 85389099 | |
Weight: | 0.3 kg |
- Listening in, logging and analysing of asynchronous communication protocols
- Versions for RS232, RS422/RS485 and TTY
- Maximum recording speed: 115200 baud for RS232 + RS422/RS485 + TTY
- Data output in HEX- or ASCII-format
- PC for operating software requires 2 serial COM ports
- Active devices, supply-voltage 24V DC
- Measuring section can be connected to the device via screw-terminals, to a PC with D-SUB 9-pin (cable included in delivery)
- Recording-/operating-software not included in the scope of delivery
Logging and analysis of communication data
![Produkbild](images/showimage.php?prozent=65&path=../images/katalog/PGFOX-Kommunikation.png)
You want check,why your application can´t communicate with the PLC or why after some time past the communication will be broken? No problem, integrate the PG-FOX-hardware in this communication way and log through the PG-FOX-software on an PC the sended data in the exact time. So, you can later check the date and find a solution of the problem.
Logging and analysis of communication data
![Produkbild](images/showimage.php?size=227.5&path=../images/Homepage-Bilder/pgfox.png)
Supply voltage: | 24V DC |
Power consumption: | 4 watt |
Interfaces: |
to the measuring section (screw terminals):
depending on the variant:2 x RS232 2 x RS422 2 x TTY/20mA current loop
to the PC (D-sub 9pin):
2 x RS232 |
Maximum speed: |
RS232 + RS422/RS485
115200 baud
TTY:
38400 baud |
Operating temperature: | 0 - 55°C |
Case: |
powder coated metal case also suitable for screw mounting |
Dimensions: | 170 x 125 x 40 mm |
Scope of delivery: |
respective PG-FOX-module (RS232, RS422/RS485 or TTY) 2x cable 9-pin 1to1 |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
59,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
530,00 €
plus VAT. and shipping
plus VAT. and shipping
530,00 €
plus VAT. and shipping
plus VAT. and shipping
530,00 €
plus VAT. and shipping
plus VAT. and shipping
Analysis technic
![](images/showimage.php?path=Homepage-Bilder/EtherSens-Familie-mitText.png&size=150)
Networked via LAN - WIFI - LTE
Worldwide access from any device possible
Internal and external data-storage
Simple rail-mounting
![](images/showimage.php?path=Homepage-Bilder/TINA.png&size=150)
Mobile intelligent network-analyser
![](images/showimage.php?path=Homepage-Bilder/osc-19.png&size=150)
O₂-analysis 100% - 10-24 of industrial gases
19
![](images/showimage.php?path=Homepage-Bilder/OSM-HMG.png&size=150)
mobile and accurate measurement of oxygen at OSM sensors
![](images/showimage.php?path=Homepage-Bilder/9354-ANI.gif&size=150)
Analysis/diagnosis/monitoring of ProfiNet-systems
![](images/showimage.php?path=Homepage-Bilder/TINA-II.png&size=150)
Mobile intelligent network-analyser 1GB
![](images/showimage.php?path=Homepage-Bilder/Bus-Scan.png&size=150)
Plaintext display variables +++ Analyze panel-accesses +++ Determine data wo. a project +++ Recordings in web interface +++ Determine participant access +++ S7-300/400 PPI/MPI/PROFIBUS +++ Direct on bus of the S7-PLC
All prices plus costs of delivery, shipping insurance and VAT.
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
![](images/Homepage-Bilder/S7LAN-V30.png)
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
![](images/Homepage-Bilder/S5-LANModul.png)
452,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-WLAN-KLEMME
WLAN-terminal Obsolete
Successor: ALF-UA high-speed WIFI-Router for Din-Rail-mounting (Art.No: 9352-ALF-UA)
connection of a network client via WLAN to an Access-Point or in AdHoc-mode USB-drivers for parameterization only for Win XP!
WLAN-terminal Obsolete
Successor: ALF-UA high-speed WIFI-Router for Din-Rail-mounting (Art.No: 9352-ALF-UA)
connection of a network client via WLAN to an Access-Point or in AdHoc-mode USB-drivers for parameterization only for Win XP!
![](images/Homepage-Bilder/S7-WLAN-Klemme.png)
price on request
plus VAT. and shipping
plus VAT. and shipping
83,00 €
plus VAT. and shipping
plus VAT. and shipping
115,00 €
plus VAT. and shipping
plus VAT. and shipping
127,00 €
plus VAT. and shipping
plus VAT. and shipping